- Product Categories
- Friendly Links
- home > Supply > Schneider production and marketing of high-quality surge protector PR-40KA / 3P + N lightning / surge protection products warranty for two years
Schneider production and marketing of high-quality surge protector PR-40KA / 3P + N lightning / surge protection products warranty for two years
Information Name: | Schneider production and marketing of high-quality surge protector PR-40KA / 3P + N lightning / surge protection products warranty for two years |
Published: | 2015-07-16 |
Validity: | 300 |
Specifications: | PR-40KA / 3P + N |
Quantity: | 1000.00 |
Price Description: | |
Detailed Product Description: | Yueqing Lei Chung electrical production and operation OBO, ABB, Schneider and other series surge protector for sale, cheap, large favorably, welcome advice to buy the pro, can also be customized. First, the use of lightning arresters electrical one, is one of the widely used electrical. For arresters we all know some, this is not the lack of high-rise buildings. Arrester similar harmonic elimination, divided into many. CHINA Electrical boutiques to introduce you to several of the arrester model. Distribution arresters: used to protect distribution transformers, switchgear, box-type variable, cable head column switches and other small oil distribution equipment from atmospheric over-voltage and over-voltage damage. Plant arresters: used to protect power plants, substations equipment from atmospheric over-voltage and over-voltage damage. Parallel compensation capacitor arresters: vacuum switch for suppressing or less oil switch capacitor switching overvoltage generated renewed protect the capacitor bank from operating over-voltage damage. Its use: Ambient temperature -40 ℃ - + 40 ℃; altitude less than 2000m; power frequency 48Hz- 62Hz; seismic intensity of 7 degrees and the following areas; maximum wind speed does not exceed 35m / s; long applied to the arrester work frequency voltage should not exceed its continuous operating voltage. Second, Schneider surge protector commonly used models PR Series pluggable surge protection technical parameters of the maximum discharge current Imax (8 / 20μs): PR 120/65/40/20 / 10kA nominal discharge current In (8 / 20μs ): 60/35/20/10 / 5kA voltage protection level PR Up: PR 2.1 / 2.0 / 1.5 / 1.2 / 1.0kV Reference Descrtption No. Description PR pluggable surge protector 916870 PR 120 r 120kA 1P 1781.1 916800 PR 65r 65kA 1P 340V 952.3 916802 PR 65r 65kA 1P + N 340V 1993.3 916803 PR 65r 65kA 2P 340V 1820.8 916804 PR 65r 65kA 3P 340V 2949.0 916806 PR 65r 65kA 3P + N 340V 3527.4 916807 PR 65r 65kA 4P 340V 3185.2 916808 PR 40r 40kA 1P 340V 753.0 916809 PR 40 40kA 1P 340V 494.3 916812 PR 40r 40kA 1P + N 340V 1417.2 916813 PR 40 40kA 1P + N 340V 1010.1 916814 PR 40r 40kA 2P 340V 1332.2 916815 PR 40 40kA 2P 340V 968.0 916816 PR 40r 40kA 3P 340V 2004.1 916817 PR 40 40kA 3P 340V 1455.5 916820 PR 40r 40kA 3P + N 340V 2699.6 916821 PR 40 40kA 3P + N 340V 1739.9 916822 PR 40r 40kA 4P 340V 2530.5 916823 PR 40 40kA 4P 340V 1583.3 916844 PR 20r 20kA 1P 340V 683.4 916824 PR 20 20kA 1P 340V 437.4 916825 PR 20r 20kA 1P + N 340V 1207.2 916826 PR 20 20kA 1P + N 340V 827.8 916847 PR 20r 20kA 2P 340V 1134.9 916827 PR 20 20kA 2P 340V 817.0 916848 PR 20r 20kA 3P 340V 1717.0 916828 PR 20 20kA 3P 340V 1135.1 916850 PR 20r 20kA 3P + N 340V 2474.1 916830 PR 20 20kA 3P + N 340V 1508.0 916851 PR 20r 20kA 4P 340V 2251.5 916831 PR 20 20kA 4P 340V 1372.2 916832 PR 10 10kA 1P 340V 365.5 916834 PR 10 10kA 1P + N 340V 836.1 916835 PR 10 10kA 2P 340V 760.7 916836 PR 10 10kA 3P 340V 1102.3 916838 PR 10 10kA 3P + N 340V 1471.8 916839 PR 10 10kA 4P 340V 1365.3 PR replaceable part 916867 D120-340 1428.3 916840 D65-340 714.1 916843 D40-340 376.5 916846 D20-340 343.3 916849 D10-340 274.7 916842 DGn 369.2 Third, mine selection, installation and maintenance of electrical and our lives, good or bad quality electrical products directly related to the security of our property lives, so this remind parents who buy When electrical products, must be careful, carefully selected, not too much covet cheap, so buy inferior merchandise causing you unnecessary losses of trouble, and finally I wish pro happy shopping. First, classification and selection arrester arrester selection. From the actual use of the situation, lightning damage in most cases is due to the lightning arrester action is too often result, and this part is because of lightning caused by improper selection, so the correct selection of the security lines and equipment to crucial. Arrester selection of the most important is the nominal voltage selection: should make it higher than it might appear during the installation of the power frequency voltage transients. In llOkV and above the neutral point grounding system can be selected as described above. Second, the installation of a newly installed lightning arrester, said selection requirements should first check whether its voltage level is consistent with the protection device. The first two new clothes and re-install (no thunder of decommissioning) must be measured frequency AC and DC voltage test leak test and insulation resistance up to standard requirements can not be used. Top 3 installation, you should check the arrester is intact. Its surface should be no cracks, no damage; seal should be intact, should be closely connected; metal contact surfaces should be cleared of the oxide layer, dirt and foreign matter, to protect clean. Third, the maintenance of the arrester (a) preventive tests. Working for many years under the combined weather conditions, electrical and so on. Arrester performance may change, in order to detect potential safety problems, the arrester to deal runs until the advent of the thunderstorm season for preventive tests. (B) visits to check the arrester. 1 Check the appearance of damage, cracks, contamination and discharge phenomenon. Because the damage, cracks, contamination in the humid air, under applied voltage, leakage current will significantly increase the arrester appearance, reduce the discharge voltage. After 2 each thunderstorm lightning counter to check whether the action, check lightning counter is intact. 3 Check the terminal fitting is solid, the lead is disconnected, broken stocks, burned traces. 4 Check abnormal sound inside the arrester. 5 Check the arrester mounting loose. Fourth, hazards and hazardous mine tips lightning hazards caused by different forms of lightning and other factors, it is lightning fast attacks, before people had not heard thunder shock, but too late to escape. Moreover instantly struck by lightning caused buildings, warehouses, depots and other fire and exploded, causing enormous material and human losses and casualties. Although it has increased awareness of the lightning, and take some lightning protection measures, however, lightning involves many uncertainties, although we generally determine the lightning discharge behavior of a particular form, but can not guarantee that will not deviate from this form of lightning discharges so lightning is a very important fire safety measures. When a lightning storm should avoid entering and proximity: without the protection of small buildings, warehouses, sheds and the like; not take lightning protection tents and temporary shelters; non-metal roof or hood of the car; open fields, playgrounds, swimming pool, lake and waterfront, barbed wire, clothesline, overhead lines, isolated trees. Avoid using or touching electrical equipment, telephones and plumbing fixtures, as soon as possible and taken refuge: Take lightning protection measures for residential and other buildings; underground shelters, subways, tunnels and caves; large metal or metal frame structure; a metal Cars and other vehicles closed roof. We should seek to avoid low-lying areas and upland hill, look for dense woods. If you are in an exposed area, alone, when the lightning comes, you feel the hair put up, indicating that the lightning, you should immediately squat body bent forward, and hands on knees. Do not lie flat on the ground, nor put his hand on the ground. |
Admin>>>
You are the 10749 visitor
Copyright © GuangDong ICP No. 10089450, Yueqing Lei Chung Electric Co. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 10749 visitor
Copyright © GuangDong ICP No. 10089450, Yueqing Lei Chung Electric Co. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility